IDM Web Capture — user guide
Updated: 29 October 2026

Purpose and privacy

IDM Web Capture is a community diagnostic tool for improving the IDM integration for Home Assistant. It reads your local Navigator and saves a ZIP on your computer. It does not write settings, operate coils, unlock service access, execute downloaded scripts or automatically upload diagnostics. Recognized direct identifiers are removed before storage. Technical data remains and may be distinctive; complete anonymity is not guaranteed. Never attach a diagnostic ZIP to a public GitHub issue.

Language

The first start uses your Windows UI language or Linux locale: German for German systems, English otherwise. Choose Language > Deutsch, English or System language to change it. The preference is stored locally and survives application updates. Choosing a language does not restart a capture or submit data. In the console: --language en, --language de or --language auto. The website has a visible DE / EN switch, remembers your choice locally and otherwise uses your browser language. Original third-party license texts and captured controller replies retain their original language.

1. Start the application

Windows 10/11 x64: extract the entire ZIP and open “IDM Web Capture.lnk”. Keep the complete folder; do not copy the shortcut alone. The original CPython runtime is included, so no Python installation is needed. Use About > Create desktop shortcut if desired. Keep the extracted folder and recreate the shortcut after moving it. Managed updates retain the active version and one fallback after a successful start; your original portable folder and personal diagnostic ZIPs are not cleaned up. Existing older Start-IDM.cmd launchers remain compatible. Console: Werkzeuge/Diagnose-Konsole.cmd. Alternative start: Werkzeuge/Start-ohne-Symbol.cmd.

Linux / SSH: extract the Linux tar.gz and run ./idm-web-capture <IP-address>. Python 3.11+ is required from your distribution; no pip packages are needed. For a graphical session, install your distribution’s Tk package (Debian/Ubuntu: sudo apt install python3-tk), then run ./idm-web-capture --gui. The CLI works without a display and over SSH. From 1.19.4 Linux/source application updates install automatically and require the openssl command. Versions through 1.19.3 need one manual upgrade. Update Python through the OS package manager.

Supported source targets: Linux x86/32-bit, x64, ARM32 and ARM64 with a matching Python interpreter. The bundled Windows runtime is x64 only. Windows x86/ARM64 need a matching official Python and the complete source package. Windows ARM32 is unsupported. Native validation covers Windows x64 and Ubuntu 24.04 x64/Python 3.12; other architectures were not hardware-tested.

Read the terms and choose Accept & continue. You can read bundled component licenses offline in Help > Licenses & third parties, THIRD-PARTY-NOTICES.txt and licenses/.

2. Connect to your Navigator

Enter the IP address or hostname, without http://, path or port, and your web PIN. The PIN is used for local login and is not saved in the ZIP. Without a web PIN, only Modbus data can be captured. If you use a proxy/gateway, enter its Modbus address, port and unit ID. Leave the Modbus host empty to use the Navigator address. Choose an output folder and Start capture. The client and controller must be reachable on the same network or your own routed network/VPN.

Navigator 2.0 HTTP, Navigator 10 WebSocket and known Modbus reads are attempted as selected. Known register plans cover Navigator 1.0/1.7/2.0/10/Pro; legacy c3000–c3003 command bits are read using FC01. Common addresses do not prove the controller model. Not every controller has every interface or optional module. Missing web data does not automatically make the whole capture unusable.

3. Capture duration and results

The progress view shows elapsed progress and an approximate remaining time. A reference run on 28 October 2026 with tool 1.16.0 took 3 minutes 17 seconds for Navigator 10, including web, Modbus, sanitization and ZIP creation. User input, updates and uploads were excluded. This is one reference, not a duration guarantee; slower networks, unavailable interfaces and timeouts can take longer.

A filename such as idm-nav20-20261023T123456Z-a1b2c3d4e5f6.zip contains an interface/category hint, UTC capture time and random identifier. It contains no serial number or myIDM identity. The result lists successful interfaces, partial reads and warnings. Even an archive containing only error details may help troubleshooting.

0/50 Modbus words means zero of fifty requested register words could be read, not fifty measured values equal to zero. Address holes or optional modules may reject reads. Partial multiword values are rechecked together with their documented length. Legacy coil bits are momentary command-bit snapshots, not persistent heating/cooling/hot-water states. No coil is written.

4. Sanitization and integrity

Before saving, the app removes recognized PINs/passwords, myIDM/serial/session/device identifiers, IP/MAC addresses, hostnames, Wi-Fi names and recognized personal names/contact/location fields. Images, fonts, embedded image data and uninspectable binary content become marked placeholders. Technical measurements, operating states, register/menu/page structures, model/software information and timestamps remain exclusively to improve the IDM integration.

manifest.json records processing. Device URLs use controller.invalid, resource names are neutral, original-response hashes are removed, and SHA256SUMS.txt is generated for the files actually saved afterwards. Matching hashes prove consistency, not authentic measurements: a sender could regenerate the ledger. There is no server authenticity seal.

Older archives: Sanitize ZIP … creates a separate copy. The original ZIP, previous receipts and uploaded copies are unchanged. Console: python idm_web_capture.py --anonymize old.zip --out destination. Review the new copy before uploading. Older clients or files without the current sanitization revision may be rejected. The current app checks the actual archive for further removable identifiers before sending.

5. Review the local ZIP

Use View diagnostics … in the menu, after capture or from the upload dialog. Existing archives can also be opened. The viewer checks file hashes first, then shows Overview, Values, Web menus, Privacy and Files & checksums. Search values or select a known model for Modbus interpretation. A model selection is not device detection. Missing values remain missing; no zero values are invented. Raw words, sentinels, partial reads and warnings remain distinguishable.

The viewer does not change the ZIP, contact the plant or upload it. It displays HTML/JavaScript as text and binary content as hexadecimal data; scripts and links are not executed automatically. The privacy search is only a review aid, not proof of complete anonymity. Main-app update checks may continue independently.

Display limits: values show at most 2,000 matches per filter; menu/privacy lists show at most 5,000 entries with totals. Raw previews are limited to 256 KiB. Narrow the search to inspect more results. The original ZIP is preserved. The viewer accepts ZIPs up to 128 MiB, but direct upload is limited to 32 MiB. Console: --view capture.zip; verify only: --verify capture.zip.

6. What the web archive includes

The capture follows local links and saves HTML, JavaScript and lazy-loaded modules, CSS and translations. Images/fonts/binary resources become placeholders before saving. Navigator 10 advertised settings submenus and detail responses are followed recursively; room, statistics, graphs and plant entries are discovered from device replies.

After extracting the diagnostic ZIP, web/index.html lists sources and nav10/menu_index.html lists menu/detail requests and parent menus. JSON indexes record sanitized URLs, neutral filenames, replies, failed requests, empty results, skipped actions, unresolved reads and discovery limits. The result is not an interactive offline clone and cannot include server-side source code. External links are recorded, not fetched. No form submission, action execution or access-level unlocking occurs.

Limits: 1,200 HTTP resources, 64 MiB total, 8 MiB per resource, 2,000 extra menu requests and ten minutes per discovery phase. Reached limits are reported as incomplete coverage. Upload remains limited to 32 MiB compressed. Tool-authored labels follow the app language; original controller values, names and source replies retain their captured language.

7. Optionally donate privately

Choose Upload diagnostics privately …, review file, size, destination and 90-day retention, and read Privacy & details offline. Optionally choose the Navigator category, enter an integration GitHub issue number or URL, and add a comment of at most 200 characters. Do not enter a PIN, passwords or personal information. Category hints are marked as user input.

Tick “I agree to upload exclusively to improve the IDM integration” and choose Upload now. Opening the dialog does not send data. Consent is required for each selected ZIP; it is not preselected or stored for future uploads. A progress bar shows transfer, then waiting for storage/confirmation. The local ZIP is retained.

Sent: the selected ZIP, size, SHA-256, tool version, sanitization revision, capture ID and optional category/comment/issue reference. Metadata is sent while preparing the upload, before the ZIP has fully arrived. The server sees your connection IP. HTTPS protects transfer; private server storage is AES-GCM encrypted and requires operator authentication. There is no server-side malware scan. ZIP format, entry/size limits and hashes are validated before storage. Archives are never executed or served as active web pages. Data is used exclusively to improve the IDM integration for Home Assistant, including bug fixes and Navigator/device/register support. Donors need no account.

Console upload: ./idm-web-capture --upload capture.zip --issue 577 --comment "Problem description" --language en. In an interactive console, only the requested confirmation (“yes” in English, “ja” in German) sends. Without a terminal, nothing is sent unless you explicitly pass --consent-upload for the chosen file. Uploads are never automatically retried.

8. Keep the receipt

After matching server confirmation, the app shows the reference number, server filename, receipt time, size, SHA-256 and the additional metadata sent. The receipt is saved beside the ZIP as .upload.json and may contain your comment. Treat it as private. Copy reference number makes support enquiries easier. A saved receipt is shown again if its hash matches the selected ZIP; this is a local record, not a new server status query. The server filename may differ because it uses the selected category and receipt identifier.

After successful storage, the server reviews response structures exclusively to improve the IDM integration. The operator is emailed through the existing mail server only for new technical structure findings; ordinary reading changes, known structures and previously reported findings do not produce another notice. The email includes receipt number, receipt time, optional GitHub issue reference, protected comparison link and counts of new replies, fields or changed types. It contains no ZIP, measurements, field names, device identifiers, comment, category or network address. Operator authentication is still required. Mail failures are retried independently of storage. The mailbox copy is separate from automatic 90-day inbox deletion; mail-server connection data is generated when sending.

Private uploads and their index are retained for 90 days from receipt and removed at the next successful automatic cleanup. Local files, operator downloads and email copies are separate. Withdrawal/early deletion: git@xerolux.de, preferably with the reference number. See PRIVACY-en.txt for full details.

9. Updates

From 1.19.4, a newer signed release installs and restarts automatically before capture or upload. A known update or invalid verification blocks capture; retry or exit on failure. Download progress shows MiB and percentage; verification, extraction and runtime checks are animated. The updater verifies signature and file hashes and retains one fallback version. Failed startup can roll back. Existing diagnostic ZIPs are preserved. Without network access, the app starts normally for local capture. Linux/source application updates use the same mandatory policy and require the openssl command. Versions through 1.19.3 need one manual upgrade. System Python updates through the OS package manager. The Windows runtime is included in complete application packages; About shows the version and exact executable actually running.

10. Troubleshooting and email alternative

• No network: capture locally if the controller is reachable; upload later when Internet access returns.
• Upload not confirmed: metadata and part or all of the ZIP may already have arrived. Sending again may create duplicates. Check a saved receipt or contact git@xerolux.de with time period/tool version/reference, without PIN or another public archive.
• Earlier HTTP 503 from antivirus: that server-side gate was removed. You can submit the existing local ZIP again without a new capture.
• Preparation rejected: update the app and create/review a separate sanitized copy if the archive is older.
• Receipt cannot be saved: copy the reference number. A local receipt failure does not undo confirmed server storage.
• Confirmed but no support reply: receipt proves storage; delayed email or support response does not require another upload.
• File too large or upload unavailable: choose Alternatively, email … and manually attach the ZIP in your own email application to git@xerolux.de. Opening the email application sends nothing by itself. Do not duplicate an already confirmed donation.
• Technical names missing from a capture made with an older redaction version cannot be recovered from that ZIP. A fresh current capture is needed to obtain those original labels.

11. Source, licenses and links

Complete source package: https://idmtools.xerolux.de/en/#download
English website guide: https://idmtools.xerolux.de/en/anleitung.html
Privacy: https://idmtools.xerolux.de/en/privacy.html
Licenses: https://idmtools.xerolux.de/en/licenses.html
Home Assistant integration: https://github.com/Xerolux/idm-heatpump-hass

With your own Python: extract the complete source package and run python idm_web_capture.py <IP-address> --language en. The PIN is requested without echo. Never copy only one source file: keep the catalog, language files and companion modules together. Original third-party license texts remain in their original language. Public software scan results concern the software package, not donated diagnostic archives; they do not guarantee future Defender/SmartScreen acceptance.

The website gallery uses synthetic data only. Public donation statistics contain only aggregate category counts from the last 90 days, updated about hourly. They count submissions, not unique people/plants; category hints are not verified model identities. No individual files, notes or identifiers are public. Statistics do not determine whether your particular model is fully supported.

Donated before? A code derived from the serial number helps us group submissions from the same heat pump and compare changes. The serial number itself is not transmitted.
Only when the serial is accessible and unambiguous. See Privacy for details. The code can be reviewed in the local viewer and manifest.

Since 1.18.1: an SVG request returning fallback HTML is recorded as an unavailable asset without following its links again. The operator can exclude confirmed test submissions from public statistics; reviewed genuine donations remain counted.

NAVIGATOR 10 is the heat-pump controller. NAVIGATOR Pro is the optional individual room control, for example for underfloor-heating zones. A WebSocket connection does not prove Pro equipment. The display includes legacy combined WebSocket categories under Navigator 10; stored submissions are unchanged.

The display shows elapsed time and, once enough measurements are available, an estimate for the current step. Newly discovered menus and waiting periods can change it; an overall remaining time is not always predictable. Upload and consent stay in fixed footers. Raw statistic replies and statistics_index.json are included under nav20/ or nav10/; the manifest counts saved replies and replies with data. Missing replies are never filled with zeroes.

MODBUS TROUBLESHOOTING
The ZIP distinguishes deliberately disabled capture, refused connections, timeouts, network failures, unavailable registers and internal tool failures. Without a separate Modbus IP, the plant IP is used. For refusal, check IP/port (usually 502), controller Modbus TCP enablement with the installer, firewall and any proxy. Refusal alone does not prove its exact cause. The manifest and viewer record selection, target source and connection/read attempts without private addresses.

CONTROLLER IDENTITY AND WEB TRANSPORT
HTTP and WebSocket are read paths, not proven controller models. HTTP compatibility success must not automatically identify Navigator 2.0. The ZIP records controller_identity from explicit response metadata or unknown. NAV10_ and T_NAV10_ software-version fields indicate Navigator 10; missing/conflicting metadata remains unknown. Legacy nav20/nav10 folders and names are compatibility/interface categories, not model or authenticity proof. A manually selected upload category remains a user declaration.


Web authentication and failure evidence (1.19.3)
----------------------------------------------
If a PIN was supplied but neither web interface yields usable data, the GUI
pauses before further capture. Choose Correct connection details, Continue
without web data, or Cancel. Correction preserves the address/proxy but requires
a fresh PIN entry; the previous failure ZIP remains intact. A returned login
form does not prove an incorrect PIN: an unsupported authentication flow is also
possible. Try a fresh private-browser login with the same details. Never send
us a PIN. web_diagnostics.json and sanitized login responses preserve attempted
paths/field names, HTTP status, form structure without values/query strings,
redirect path, elapsed time and outcomes. Known PIN, CSRF and session fields are
removed before saving. Each login response is limited to 64 KiB; truncation is
marked. Discovered forms are documented, never automatically submitted. One
working HTTP or WebSocket interface is sufficient. No PIN means web was disabled
intentionally. Terminal/SSH: noninteractive web failure preserves an evidence ZIP
and cancels further capture unless --continue-without-web was explicitly chosen.
No upload occurs automatically. Purpose and retention remain unchanged.

Mandatory updates and submissions (1.19.4)
When the update service is unreachable, local capture is still available; manifest.json records update_check. Invalid signatures are not an offline case and block capture. After a successful restart the active version and one verified fallback are retained; personal ZIPs are preserved. Current captures are preferred, but older tool versions are accepted too. Existing ZIPs remain uploadable after an app update. Format, size, sanitization and checksum checks still apply. Already issued upload tickets and stored donations remain valid.

Privacy filtering and web archive (1.19.6)
Known local access codes and personal circuit/room labels in HTTP settings lists are removed. Technical IDs, measurements, offsets and units remain available. Before sharing an older ZIP, use Clean ZIP to create and locally review a new checked copy. Originals are not overwritten. This does not guarantee anonymity. JavaScript references use the appropriate browser base; unavailable resources remain visible as failures in the archive index.

Coils in the Values tab (1.19.7)
Open View diagnostic → Values and select Modbus coil to see stored bits with on/off, address and source file. With matching catalog/model interpretation, c3000–c3003 use reviewed command labels: acknowledge errors, request heating, request cooling and request DHW priority charge. On/off describes only the captured command bit, not persistent heating/cooling/DHW operating states. Unknown addresses remain unassigned. Viewing never connects to the plant, writes or changes the ZIP. Older diagnostic ZIPs work too; no new capture is needed.